ENGINEERING IN PERU · INTERNATIONAL ENQUIRIES

BBS · FIRE ALARM SYSTEMS

Fire detection.
Engineering for every facility.

Smoke detectors, XLS, NOTIFIER, Fire-Lite and Simplex panels. Find the part number and engineering your facility needs.

Honeywell XLS4000 panel; illustrative manufacturer configuration

XLS4000

Honeywell XLS3000 panel; illustrative manufacturer configuration

XLS3000

Honeywell XLS140-2 panel; illustrative manufacturer configuration

XLS140-2

Honeywell XLS120 panel; illustrative manufacturer configuration

XLS120

Detect

Devices selected against risk and environment.

Process

Panel, loops and logic defined by engineering.

Notify

Notification and handling of agreed events.

Supervise

Documented interfaces for operations.

HONEYWELL XLS

Explore the panel in your facility.

Select a model to view its technical profile and open its overview.

Honeywell XLS4000 panel; illustrative manufacturer configuration
Illustrative configuration · Honeywell

HONEYWELL · XLS4000

Configurations for your project

A platform with integrated configurations and modular options. Selection starts with the required architecture.

SLC loops¹

1–3 / 1–10

Max. addresses¹

954 / up to 3,180

Architecture

Integrated or modular

Reviewed reference: HON-62112:B · 25/09/2025. Sheet supplied for technical review.

Honeywell XLS3000 panel; illustrative manufacturer configuration
Illustrative configuration · Honeywell

HONEYWELL · XLS3000

Modular architecture

An addressable panel for medium and large facilities, with expansion through loop modules.

SLC loops¹

1 to 10

Max. addresses¹

Up to 3,180

Architecture

Medium and large scale

Official technical sheet · EN ↗74-4034-16 · 14/09/2022

Honeywell XLS140-2 panel; illustrative manufacturer configuration
Illustrative configuration · Honeywell

HONEYWELL · XLS140-2

Expansion from one to two loops

An addressable panel with one onboard loop and expansion to two, depending on the configuration.

SLC loops¹

1 expandable to 2

Max. addresses¹

Up to 636

Architecture

Expandable architecture

Official technical sheet · EN ↗85-3128-13 · 14/09/2022

Honeywell XLS120 panel; illustrative manufacturer configuration
Illustrative configuration · Honeywell

HONEYWELL · XLS120

One addressable loop

A panel for small and medium facilities, with one addressable signalling circuit.

SLC loops¹

1

Max. addresses¹

Up to 318

Architecture

Small and medium scale

Official technical sheet · EN ↗74-5144-11 · 14/09/2022

← Swipe the table to compare →

Compare models
ModelSLC loops¹Max. addresses¹Sheet revision
XLS4000 ↗Integrated / modular CPU1–3 / 1–10954 / up to 3,180HON-62112:B · 25/09/2025
XLS3000 ↗1 to 10Up to 3,18074-4034-16 · 14/09/2022
XLS140-2 ↗1 expandable to 2Up to 63685-3128-13 · 14/09/2022
XLS120 ↗1Up to 31874-5144-11 · 14/09/2022

¹ Documented capacity depends on protocol, modules, licences and configuration. SLC: signalling line circuit. Figures do not establish compatibility, availability or equivalence between models.

INTEGRATION WITH CONTEXT

One event.
The information your operators need.

We assess connections between fire alarm, supervision, ventilation, access and video. Validate each connection against model, version, interface, licences and the cause-and-effect matrix.

Explore our integration approach →

Fire alarm system

XLS

EBI supervision

HVAC

Access

Video

Conceptual diagram. Safety logic remains in the designated systems; a common display does not imply control permissions.

BBS ENGINEERING

Understand your system.
Define the next step.

Initial assessment

Inventory, versions, backups and event history. Findings prioritised by criticality.

Intervention plan

Scope, owners, work window, contingency and acceptance.

Execution and testing

Change control and tests of authorised interfaces.

Closeout and follow-up

Evidence, open items and recommendations reviewed with the client.

Interventions are agreed with the technical lead and operations. Depending on scope, test protocols and reports may require a licensed engineer’s signature.

A MULTIBRAND PERSPECTIVE

Your system belongs here too.

Honeywell XLSNOTIFIERFire-LiteEdwardsKiddeMircomHochikiSimplexVESDA / Xtralis

Explore fire system brands →

YOUR FACILITY COMES FIRST

Which panel is installed?

Tell us the model, site and what you need to resolve.

CROSS-REFERENCE GUIDE

Honeywell XLS
and NOTIFIER.

Identify comparable panels and the evolution of TC806B, TC808B, FSP and FST detectors.

Open the guide →
Honeywell XLSNOTIFIER INSPIRE / ONYX

DEVICES AND DOCUMENTATION

References for your project

Select by application and model. Architecture, interfaces and availability are reviewed before quotation.

Mircom FX-401 · product reference
Mircom FX-401 · product reference

Mircom

FX-401

Addressable fire detection and alarm panel.

Selection and documentation

Design loops, devices and notification using the specific documentation and project engineering.

Read manufacturer source ↗

Referencia pública del fabricante / Public manufacturer reference · Source checked

Hochiki ALO-V · product reference
Hochiki ALO-V · product reference

Hochiki

ALO-V

Hochiki multi-criteria smoke detector.

Selection and documentation

Validate protocol, base, panel and system approval. A shared brand does not imply interchangeability.

Read manufacturer source ↗

Referencia pública del fabricante / Public manufacturer reference · Source checked

System Sensor P2RLED · product reference
System Sensor P2RLED · product reference

System Sensor

P2RLED

L-Series indoor LED horn strobe.

Selection and documentation

The pictured reference is marked FIRE. P2RLED-SP is marked FUEGO and P2RLED-P is plain. Validate power, synchronization and mounting.

Read manufacturer source ↗

AVDS916-01 · 2023 · Source checked

BBS

What are you looking for?

Examples: