Fire-Lite: control panels, detection and devices for projects, replacement and modernisation. Technical review and supply according to each installation.
Fire & Life Safety · Honeywell Building Automation. BBS assesses supply, installation, maintenance and modernisation by model, documentation and project scope. These lines are distinct from our authorised Honeywell Building Solutions scope in Peru.
SD365 smoke detectors, H365 heat detectors, BG-12 stations, modules and ES panels. Find a part for your installed system or ask about the selection for a new project.
Equipment and parts · Fire-Lite
Search by code, description or function. Each record retains its source and review date.
Smoke detection for the technical selection of your fire alarm system.
References: SD365
Scope and documentation
Supply, variant, panel, protocol, base, power and programming are confirmed before quoting. Publication does not establish stock or universal compatibility. Manufacturer lifecycle information requires confirmation for the exact variant and market.
Ivory addressable photoelectric detector for compatible Fire-Lite systems.
References: SD365-IV
IV variant: LiteSpeed or CLIP, depending on panel
Documented supply: 15–32 V DC
Base and accessories selected separately
Scope and documentation
Verify the exact suffix, supported panel and protocol, firmware, base, installation documentation and regional availability before quotation. Shared appearance does not establish compatibility.
Smoke detection for the technical selection of your fire alarm system.
References: SD365T
Scope and documentation
Supply, variant, panel, protocol, base, power and programming are confirmed before quoting. Publication does not establish stock or universal compatibility. Manufacturer lifecycle information requires confirmation for the exact variant and market.
Smoke detection for the technical selection of your fire alarm system.
References: SD365CO
Scope and documentation
Supply, variant, panel, protocol, base, power and programming are confirmed before quoting. Publication does not establish stock or universal compatibility.
Photoelectric detector with remote-test capability for duct applications using a compatible housing.
References: SD365R
White SD365R variant: LiteSpeed
DNR/DNRW housings subject to configuration
Do not confuse with a complete open-area detector
Scope and documentation
Verify the exact suffix, supported panel and protocol, firmware, base, installation documentation and regional availability before quotation. Shared appearance does not establish compatibility.
Heat detection; response type is selected for the application.
References: H365
Scope and documentation
Supply, variant, panel, protocol, base, power and programming are confirmed before quoting. Publication does not establish stock or universal compatibility.
Selection depends on environment and detection design
Scope and documentation
Verify the exact suffix, supported panel and protocol, firmware, base, installation documentation and regional availability before quotation. Shared appearance does not establish compatibility.
Addressable high fixed-temperature heat detector for applications requiring this threshold.
References: H365HT
Nominal threshold: 88 °C (190 °F)
White H365HT: LiteSpeed protocol
Verify permitted ambient temperature and base
Scope and documentation
Verify the exact suffix, supported panel and protocol, firmware, base, installation documentation and regional availability before quotation. Shared appearance does not establish compatibility.
Heat detector combining a fixed threshold with rate-of-rise response.
References: H365R
Fixed threshold: 57 °C (135 °F)
Nominal rate of rise: 8.3 °C/min (15 °F/min)
White H365R: LiteSpeed protocol
Scope and documentation
Verify the exact suffix, supported panel and protocol, firmware, base, installation documentation and regional availability before quotation. Shared appearance does not establish compatibility.
BG-12 family. This photograph does not identify the BG-12LAO variant.
Fire-Lite
BG-12LAO · Manual alarm pull station
BG-12-family manual activation point. Review the variant and its interface with the existing system.
References: BG-12LAO
Technical assessment
Manufacturer documentation
Scope and documentation
Confirm BG-12LAO by complete code and applicable documentation. The photograph shows the BG-12 family; it does not establish this variant’s backbox, contacts, labelling or environmental protection.
Manual alarm activation. We check circuit type, language and mounting.
References: BG-12LSP
Scope and documentation
Supply, variant, panel, protocol, base, power and programming are confirmed before quoting. Publication does not establish stock or universal compatibility.
Manual alarm activation. We check circuit type, language and mounting.
References: BG-12LXSP
Scope and documentation
Supply, variant, panel, protocol, base, power and programming are confirmed before quoting. Publication does not establish stock or universal compatibility.
Confirm power supply, regional variant, communicator and supported devices. Nominal capacity does not replace loop, power and notification calculations.
Complete the solution
Audible and visual notification
Horns, strobes and speakers with documented circuits and synchronisation.