ENGINEERING IN PERU · INTERNATIONAL ENQUIRIES

ACCESS CONTROL · LENELS2

LenelS2 OnGuard: access control for offices and buildings

Explore OnGuard software, M-Series controllers, interface modules, readers and credentials. Technical selection, supply assessment and services for your project in Peru.

People · Doors · Operations

Define who enters, where and when.

An access control solution brings together people management, field equipment and operating rules. In offices, it helps organize access to reception, workspaces and restricted areas, with traceability for the security team.

  1. 01 · IDENTIFICATIONCredential + readerA compatible physical card or mobile credential is presented.
  2. 02 · LOCAL CONTROLController + doorAccess permissions and door status are checked.
  3. 03 · MANAGEMENTOnGuardPeople, schedules, events and operators are managed.
  4. 04 · INTEGRATIONVideo + applicationsVerified interfaces support the project scope.

BBS functional illustration. Final architecture depends on the site inventory, licenses, network and requirements.

Management platform

OnGuard: from credentials to monitoring.

PEOPLE

Credentials and permissions

OnGuard Credentials manages people, badges and access levels. Define roles and responsibility for enrollment and revocation.

OPERATIONS

Events and monitoring

OnGuard Monitor supports browser-based monitoring. Define relevant events, operator permissions and response procedures.

VISITORS

Visitor management

Visitor supports visits through a browser client. Agree the reception workflow, approvals and data handling.

GROWTH

Sites and integrations

Enterprise supports multiserver operations. Video and external applications depend on their interfaces and licenses.

What OnGuard 8.4 adds

The current datasheet includes mutual TLS (Transport Layer Security) authentication between servers and controllers, message-broker high-availability improvements and browser-client updates for license usage, administration, audio notifications and visitor management. It also documents Honeywell 35 Series video integration.

Verify components, revision and licenses for these capabilities. An upgrade requires a validated backup, work window, contingency and testing. Read the release datasheet ↗

OnGuard Cloud is a separate deployment option. Availability in Peru, hosting, connectivity, data handling and commercial terms must be verified before it is offered. Features and modules are not automatically included in every license.

Hardware selection

M-Series controllers: select for your architecture.

The controller executes access logic; interface modules expand readers and field signals. These references help compare options and prepare an evidence-based bill of materials.

Single door · distributed control

LNL-M2210

Controller LenelS2 LNL-M2210, official manufacturer photograph
Manufacturer photograph · Click to enlarge

Controller for one door with one or two readers. Supports PoE/PoE+ (Power over Ethernet) or 12 VDC power. Its datasheet describes local operation after configuration.

Check the power budget and port use; the second port does not support an OSDP reader.

Official datasheet · PDF ↗

Dual reader · modular expansion

LNL-M2220

Controller LenelS2 LNL-M2220, official manufacturer photograph
Manufacturer photograph · Click to enlarge

Two onboard reader ports, eight inputs and four relays. The datasheet supports one or two doors and RS-485 expansion to 32 devices, with a 64-door limit.

A reference for assessing a compact controller and expansion through modules.

Official datasheet · PDF ↗

Central controller · external interfaces

LNL-M3300

Controller LenelS2 LNL-M3300, official manufacturer photograph
Manufacturer photograph · Click to enlarge

Manages reader and input/output modules through two RS-485 buses. The datasheet allows up to 64 devices and 64 doors through the selected interface combination.

Reader interface modules are required; assess distribution by floor or area.

Official datasheet · PDF ↗

Advanced control · signal integration

LNL-M4420

Controller LenelS2 LNL-M4420, official manufacturer photograph
Manufacturer photograph · Click to enlarge

Advanced dual-reader controller, expandable to 64 doors through interfaces. Its datasheet documents exchange of up to 63 BACnet points with building automation.

BACnet requires point mapping, exchange direction and testing; it does not automatically integrate the entire platform.

Official datasheet · PDF ↗

Doors, readers and modules are different counts. One door may have entry and exit readers. Maximum expansion capacity is not the number of directly connected doors or a quoted configuration. Licenses, power, enclosures, cabling and backup must be sized.

Interface modules for system expansion

INTERFACE

LNL-1300 Series 3

Interface module LenelS2 LNL-1300 Series 3, official manufacturer photograph
Manufacturer photograph · Click to enlarge

Single reader interface with two inputs and two relays. Supports OSDP Secure Channel. Requires a compatible controller.

Official datasheet · PDF ↗

INTERFACE

LNL-1320 Series 3

Interface module LenelS2 LNL-1320 Series 3, official manufacturer photograph
Manufacturer photograph · Click to enlarge

Dual reader interface with eight inputs and six relays. With OSDP, each physical reader port can support two readers on the same door; this does not double the door count.

Official datasheet · PDF ↗

For existing X-Series or earlier installations, start with the actual inventory. Selecting M-Series requires checking the applicable OnGuard compatibility matrix, firmware, modules and upgrade path.

Readers and credentials

Identify the technology before choosing the card.

Compare three BlueDiamond reader formats using their exact manufacturer references. Credential technology, protocol and service eligibility are checked for each project.

BlueDiamond

The brochure covers multi-technology readers, mobile credentials, MIFARE DESFire EV1/EV2/EV3 and 125 kHz proximity options. NFC (near-field communication) credentials in Apple Wallet and Google Wallet require regional, model, service and licensing checks.

Its iCLASS support covers Classic/Standard; the brochure excludes Elite Key, SE and SEOS. Official brochure ↗

Validating existing cards

We review card and reader references, frequency, application and authorized keys, bit format, facility code and numbering, then agree a test with representative credentials.

The same frequency or brand does not guarantee reading or access authorization. HID Prox, iCLASS and SEOS each require an appropriate reader selection and configuration.

OSDP Secure Channel and Wiegand: what to check

OSDP (Open Supervised Device Protocol) provides bidirectional communication between readers and interfaces. The listed modules document Secure Channel. We recommend checking both endpoints, firmware and key management to enable encrypted communication; an OSDP connection alone does not prove that Secure Channel is active.

For an existing Wiegand installation, review cabling, equipment and operations before making changes. Include the decision in the modernization plan and acceptance tests.

Scope per door

A complete solution includes more than a reader.

Field equipment and conditions

  • Reader, credential, controller or interface module.
  • Lock or door hardware suitable for the opening and its use.
  • Door contact, request-to-exit and egress devices defined by engineering.
  • Sized power supply, protection, enclosure, network and backup power.

Configuration and operations

  • People, profiles, schedules, holidays and operator permissions.
  • Granted or denied access events and door supervision.
  • Licenses, servers, database and backup policy.
  • Testing, documentation and handover to the site representative.

Egress requirements and fire alarm interfaces are defined and validated with the responsible engineer. No universal release logic is prescribed; approved behavior, including loss of power, must be verified.

Integration and cybersecurity

Connect systems with a verifiable scope.

OnGuard provides interfaces with video and external applications. Identify the connector, version, licenses, permissions and exchanged data for each integration. Membership of the Honeywell ecosystem does not establish a direct EBI connection.

Video and events

Define events, cameras, permitted actions, retention and evidence retrieval. Agree a test protocol covering timestamps, operator permissions and loss-of-communication behavior.

Protecting operations

Review network segmentation, individual accounts, least privilege, certificates, restorable backups and authorized remote access. Coordinate updates with IT and document rollback; avoid exposing controllers directly to the Internet.

Explore system integration →

BBS scope

From an access requirement to a technical proposal.

BBS offers technical surveys, architecture and scope definition, supply assessment and planning for implementation, maintenance or modernization. The proposal identifies equipment, licenses, services, exclusions, responsibilities and acceptance criteria. Availability, tools and required qualifications or permissions are confirmed before committing supply or intervention.

  1. 01

    Initial diagnosis

    Door and equipment inventory, versions, licenses, faults and backups. Deliverable: prioritized findings and outstanding information.

  2. 02

    Intervention plan

    Architecture, bill of materials, permissions, work window, contingency and tests. Deliverable: agreed technical and commercial scope.

  3. 03

    Execution and testing

    Authorized work with change control. Evidence: tests of permissions, events, doors and included interfaces.

  4. 04

    Closeout and follow-up

    Report, agreed configuration records, backups, open items and recommendations. Acceptance: client-validated results.

What is needed to quote an office project?

Door count and type; entry-only or entry/exit reading; users and visitors; photographs of hardware and equipment; card technology; network and power availability; existing OnGuard version and licenses; video or integration needs; and operating restrictions.

The form accepts PDF files and photos for the initial survey. Do not attach passwords, card keys, user databases or sensitive configuration files; an authorized transfer channel can be arranged when needed.

What should be tested at handover?

Approved permissions and schedules; rejection of unauthorized credentials; events and door status; egress and contingencies as engineered; communication loss and recovery within scope; and delivery of backups and documentation. Record each door or scenario with its result, evidence and responsible person.

Protocols and reports may require a registered engineer’s signature, depending on the agreed scope.

Manufacturer documentation

Check the datasheets before specifying.

Official English-language sources reviewed on 20 October 2026. These are technical references; supply and compatibility are confirmed per project.

LenelS2 is part of the Honeywell Building Automation ecosystem. Trademarks belong to their owners. This page does not claim authorized representation, certification or official LenelS2 support for BBS. View the Honeywell ecosystem →

Need access control for your office doors?

Send us the number of access points and the information you have. We will define the next step to assess equipment, licenses and services.

Model references and documentation

BBS

What are you looking for?

Examples: